Time:2024.12.06Browse:0
Tips on equalizing charging methods for series connected UPS power supply battery packs. In recent years, batteries are being widely used in transportation, electric power, communications and other fields. In order to obtain a higher output voltage, single batteries usually need to be used in series. The editor will introduce to you the techniques of equalizing charging method of series connected UPS power supply battery pack.
Balancing principle of battery pack in series UPS power supply
1. Series UPS power battery pack is a high-power battery pack that provides power to the car in electric vehicles. In order to ensure the capacity of the entire battery pack, balanced management of the battery is necessary.
2. Various battery management ICs on the market for series UPS power supply battery packs provide voltage equalization management functions. Users only need to connect some external components to achieve this. Unfortunately, most battery management ICs use Use resistance shunting/power consumption to achieve balance between cells.
3. Series UPS power battery pack In the lead-acid battery era, various methods have emerged for balancing the battery pack.
4. Series connected lithium battery resistors shunt and consume energy. This method is the most common and simplest method on the market. The protective plates for battery packs exhibited at the 2009 Electric Bicycle Exhibition, including those for electric vehicles, are balanced by resistors. The reason is also very simple: it is easy to implement, and there is no better way. In fact, it is also the cheapest way.
Advantages and Disadvantages of Series UPS Power Battery Banks
advantage:
1. Low cost, simple structure and easy to implement.
2. Series UPS power supply battery pack is the only existing method for small companies without R&D capabilities.
shortcoming:
The disadvantages of series-connected batteries are equally obvious: waste of energy, heat generation, and low balancing efficiency, because it takes time to consume energy through resistance. In the case of high-power battery packs, this must also be considered. In fact, many large companies now use the method of connecting lithium batteries in series when making electric sprayer battery packs, but some international companies have implemented more advanced balancing methods, making energy use more efficient and balancing faster. .
Method for balanced charging of series connected UPS power battery packs
●Attach a parallel balancing circuit to each single cell of the battery pack to achieve a shunt function. In this mode, when a certain battery is fully charged first, the balancing device can prevent it from overcharging, and at the same time, the excess energy is converted into heat energy to continue charging the battery that is not fully charged.
●Pass each cell one by one before charging, discharge the same load to the same level, and then perform constant current charging to ensure a more accurate balanced state between each cell. However, due to the physical differences between individual UPS power battery packs, it is difficult for each cell to achieve a consistent effect after deep discharge. Even if the same effect is achieved after discharge, new imbalances will appear during the charging process.
●Timing, sequencing, and individual testing of individual batteries in the battery pack and even charging. When charging the battery pack, it can be ensured that each battery in the battery pack will not be overcharged or overdischarged, thus ensuring that each battery in the battery pack is in normal working condition.
●Using the time-sharing principle, through the control and switching of switch components, extra current flows into the battery with a relatively low voltage to achieve the purpose of balanced charging. This method is more efficient, but the control is more complicated.
●Take the voltage parameters of each battery as the balancing object to restore the voltage of each battery to be consistent. During equalization charging, the capacitor is alternately connected to two adjacent batteries through a control switch, receives charge from the high-voltage battery, and then discharges to the low-voltage battery until the voltages of the two batteries become consistent. This balancing method can better solve the problem of battery pack voltage imbalance, but this method is mainly used in situations where the number of batteries is small.
●The entire system is controlled by a single-chip microcomputer, and each battery has an independent set of modules. The module performs charge management on each single battery according to the set program, and automatically disconnects after charging is completed. This method is relatively simple, but it will greatly increase the cost when the number of single cells is large, and is not conducive to reducing the system volume.
Poor battery management technology and unreasonable charging and discharging systems are also important reasons for shortened battery life. For battery packs, in addition to the above reasons, the inconsistency between single cells is also an important factor.
There are currently many methods for charging UPS power batteries. Choosing a scientific and reasonable charging method will greatly improve the maintenance effect of the battery. The UPS system is highly intelligent and uses maintenance-free batteries, making it easy to use. Pay more attention to care and maintenance during use to extend the service life of the UPS power battery.
Read recommendations:
703048 1100MAH 3.7V
What is the voltage range of lithium iron phosphate battery
Capacitor batteries by electrolyte type
200ah lifepo4 battery pack 24v
18650 battery 3500mah