Time:2024.12.24Browse:0
Portable UPS power supply, the truth about future technology trends is revealed. Nowadays, portable UPS power supply is widely used in various fields because of its lightness, compactness, trolley case design, lightness to carry, and easy transportation. Such as: outdoor office, outdoor photography, outdoor construction, backup power supply, emergency rescue, etc.
Then, with the continuous development of technology and IT systems gradually moving towards centralized management, enterprises will have more in-depth application of portable UPS power protection systems. The future technology trends of portable UPS will be disclosed step by step.
1. Digitization
UPS uses the latest digital signal controller (DSP) and digitized Hall sensor devices to achieve 100% digital operation of the UPS system. A multiple microprocessor redundant system is also used, using multiple microprocessors with independent power supplies to control the rectifier, inverter and internal static bypass, thereby improving the digitalization and reliability of the system.
Low temperature lithium iron phosphate battery 3.2V 20A -20℃ charging, -40℃ 3C discharge capacity ≥70%
Charging temperature: -20~45℃ -Discharge temperature: -40~+55℃ -40℃ Support maximum discharge rate: 3C -40℃ 3C discharge capacity retention rate ≥70%
Click for details
2. Intelligence
Through the analysis and synthesis of various types of information, the intelligent system should not only complete the control function of the normal operation of the corresponding parts of the UPS, but also complete the real-time monitoring of the running UPS, analyze and process the important data information in the circuit, and draw various conclusions from it. Whether some circuits are working properly and other functions.
3. High frequency
The power switch of the first generation UPS is a thyristor, the second generation is a high-power transistor or field effect transistor, and the third generation is an IGBT (insulated gate bipolar transistor). The switching speed of high-power transistors or field-effect transistors is an order of magnitude higher than that of thyristors, and the current capacity and speed of IGBT power devices are much larger and faster than that of high-power transistors or field-effect transistors, which reduces the operating frequency of the power conversion circuit. up to 50kHz. The increase in the frequency of the conversion circuit greatly reduces the inductance, capacitance, noise, and volume used for filtering, and greatly improves UPS efficiency, dynamic response characteristics, and control accuracy.
4. Redundant parallel technology
Low temperature and high energy density 18650 3350mAh-40℃ 0.5C discharge capacity ≥60%
Charging temperature: 0~45℃ Discharge temperature: -40~+55℃ Specific energy: 240Wh/kg -40℃ Discharge capacity retention rate: 0.5C Discharge capacity ≥ 60%
Click for details
Through the development of new application technology, multi-module redundant parallel operation in portable UPS can be realized without the need for additional central control components. The load is evenly distributed. When a problem occurs in a certain module, the load is automatically transferred, and maintenance can be hot-plugged. Unplug, greatly improving the power supply reliability of a single UPS. In addition, the system composed of multiple UPS operates redundantly. If a single UPS fails, it will be shut down immediately, and other UPS systems will automatically bear the entire load without any impact on the load.
5. Integration
With the development of informatization, the application fields of power supply protection continue to expand and the requirements continue to increase. It is difficult for UPS to meet these needs alone. It must control the links involved in the entire power system. UPS starts from the initial equipment protection and system protection. Pure backup power technology has developed into today's integrated applications of information protection, intelligent management and overall computer room integration, and its connotation has expanded to power generation, power distribution, conversion, uninterruptible power supplies, computer rooms, power equipment, power cables, data cabling, and environmental monitoring. And system management, etc., it is no longer UPS in the original sense. UPS equipment is only the core component of the system.
6. Greening
The harmonic currents generated by various electrical equipment and power supply devices seriously pollute the power grid. With the introduction of various policies and regulations, the call for pollution-free green power supply devices is getting louder and louder. In addition to installing a high-efficiency input filter, the UPS should also adopt power factor correction technology at the input end of the power grid, which can not only eliminate the harmonic current generated by the rectifier and filter circuit itself, but also compensate for the input power factor. The rectifier uses IGBT technology, which can increase the input power factor to close to 1, and the pollution to the power grid has been reduced to the level of a resistive load.